ExtReports is an add-on module that provides access to predefined energy reports. The reports are adapted for different purposes, such as consumption reports.
The reports can be run at pre-defined intervals and can also be sent via e.g. e-mail or ftp.
For more information on setting up exports and transmitters, see "Custom Report" of the Web Port manual. The energy report supports export to pdf and excel file.
Installation
The installation of ExtReports is done by selecting ExtReports during the installation of Web Port.
See "Installation" for more information on the installation process.
Configuration
Configure an energy report by associating one or more tag-linked signals, and select Category. The report will when run display a table and a chart for each category that is enabled as shown in the Graphs below.
The following parameters are specific to energy reports. The others can be read more about in "Custom Report" of the Web Port manual.
- Fixed values:
These values are used to calculate and display costs in total and per m2 if enabled under Graphs.
- Graphs:
| Function: | Description: |
| Heading | Setting the title of the energy report |
| Show cost | Allows the user to view cost instead of consumption |
| Show Area | Allows the user to view values per m2 |
| Activate cost | Show cost instead of consumption |
| Activate Area | Show values per m2 |
| Forecast | Show forecast in charts as bars or lines. Can be disabled |
| Approximate month | Approximates consumption for the current month (linear approximation based on data so far this month) |
| Activate total consumption | View graph and table of total energy consumption |
| Activate energy consumption Electricity | View chart and table of energy consumption electricity |
| Activate energy consumption Heating | View diagram and table of energy consumption for heating. Adjusted downwards by Energy consumption hot water from Fixed values |
| Activate weather normalization | Normal year corrects energy consumption for heating according to values during Normalized year (requires connected outdoor sensor) |
| Enable energy signature heating | Calculates and displays energy signature based on energy consumption and daily average temperature (requires connected outdoor sensor) |
| Activate energy consumption cooling | View diagram and table for energy consumption cooling |
| Activate energy consumption hot water | View hot water energy consumption chart and table |
| Activate consmuption hot water | View chart and table for hot water consumption |
| Activate consmuption cold water | View cold water consumption chart and table |
- Normalized year
| (normalized year) heating days xx | Heating days in a normal year for the current month at the current location |